Products & Solutions
Process & Quality Control Systems VIEW INDUSTRIAL SOLUTIONS VIEW VISUM® PRODUCTS
Visum Palm™
Visum NIR In-Line™
Visum HSI™
Visum Raman In-Line™
Visum DeepSight™
Research, Development & Innovation VIEW INDUSTRIAL SOLUTIONS
Applied Photonics
AI & Digitisation
Circular Bio-economy
About us Blog Contact FAQs Join Us
  • EN
    • Español
    • Français
    • Deutsch
    • Italiano
    • Português
    • Polish
    • Turkish
Products & Solutions
About us
Blog
Contact
FAQs
Join Us
  • EN
    • Español
    • Français
    • Deutsch
    • Italiano
    • Português
    • Polish
    • Turkish
Products & Solutions

Process & Quality Control Systems

Research, Development & Innovation
KEY_INNOVATION_IRIS European Commission Highlights IRIS Technology Solutions for its Innovative Role in the AIDPATH Decentralized Advanced Therapy Production Project
NIR analyzer Control of the coating process of granular forms by NIR spectroscopy
Pharma-4-0 9 April 2024

Blending process monitoring with in-line NIR spectroscopy

blending process monitoring
Share post

Real-Time blending process monitoring with NIR spectroscopy

Powders blending process is the most popular to achieve content uniformity in solid forms. Despite its apparent simplicity, i.e., taking advantage of shear forces for mixing APIs and excipients by merely moving the container for a certain time, any specialist in galenic does know that the real behavior of the mixture is not that simple. In fact, the final distribution results from a chaotic combination of microscopic interactions among the particles and macroscopic flow mechanics, not to mention that, once the homogeneity has been achieved, there is a real risk of demixing as a consequence of the affinity among homologous particles. That is why, regardless of the mechanical improvements in the blender’s design, systematically checking for mixture homogeneity is a key requirement in the pharmaceutical and nutraceutical sector. This is where NIR becomes important as a technique for real-time blending process monitoring.

Traditional control of the blending process vs. Blending process monitoring (PAT)

Up to now, periodically stopping the blending process after several cycles in order to take some samples from different points, which are further analysed by chromatography, has been the traditional way to do it. However, such an approach has also certain unwanted drawbacks, namely added lead time (due to the involved cumbersome lab procedures), suboptimal blending time (because of arbitrary extended blending intended for guaranteeing homogeneity) and blending artifacts (such as demixing and lumps as a consequence of keeping the load in static conditions while waiting for the lab results).

 

On the contrary, a PAT approach, such as a spectroscopy-based real time blending process monitoring, could be deemed the optimal way to check if the endpoint condition has been reached. In fact, both FDA and EMA have described such an approach as a recommended new paradigm.

In principle, as thoroughly described in the scientific literature, there are two ways for implementing a PAT-based endpoint determination: by using a supervised machine learning predictive model (for example, a PLS model that quantitatively predicts the API concentration) or by using an algorithm agnostic to the specific composition of the mixture. The first one usually renders more direct and accurate results but, in turn, it requires developing specific models on the basis of suitable reference samples, which is not always feasible, especially when there are too many different formulations. The agnostic approach for blending process monitoring, on the contrary, is based on spectral similarity; no ground truth data on the specific composition of each formulation is required in advance.

The agnostic approach: Moving-block Standard Deviation and the dynamic algorithm by IRIS Technology Solutions

Spectral stability is, in fact, agnostic to the specific composition of each formulation. No quantitative predictive model has to be developed for assessing the components concentrations because the underlying rationale states that, regardless of the composition, no improvement in homogeneity can be made once the spectra remain unchanged, at least for the major components. Indeed, a mixture can be deemed homogeneous once their spectra remain unchanged after several blending cycles. 

Since the NIR spectroscopy is sensitive to 0.1-1 % or higher concentrations, during during blending process monitoring the homogeneity of minor components cannot be assessed by means of such a technology. However, it can be inferred from the homogeneity of major components and opportunely validated with traditional lab methods if required.

Moving-block Standard Deviation (MBSD) is the most widely described agnostic algorithm, at least in the scientific literature. Usually, the MBSD endpoint criterion is rather arbitrary.  Even when a statistically-founded criterion is used [Critical evaluation of methods for end-point determination in pharmaceutical blending processes. M. Blanco, R. Cueva-Mestanza and J. Cruz. Anal. Methods, 2012, 4, 2694], some restrictive hypothesis on the distribution of the similarity metric should be fulfilled in order to be properly applicable. Moreover, the mean of the standard deviation has a rather “smoothing” effect that could veil to some extent the real trend of the spectral similarity.

The dynamic approach with Visum NIR In-Line™ for blending process monitoring

IRIS Technology Solutions’ proprietary algorithm, on the contrary, is based on checking for the stability of a true similarity metric (MSD: mean squared difference between two successive spectra) by using strong statistical criteria on the blending-specific MSD distribution. In fact, our moving block approach dynamically adapts the threshold to each formulation-wise spectral-similarity statistical distribution. Consequently, it provides a robust endpoint criterion for blending process monitoring regardless of the specific behavior of each formulation, which is particularly required when mixing anomalies such as demixing or lumps formation take place. 

For the sake of flexibility, the users can set both the moving block size and the statistical significance at their convenience. Whenever possible, such parameters should be tuned in the commissioning stage although the factory-set values should work for the most frequent circumstances.

 

Image 1: Sapphire window adapter module for Visum NIR In-Line analyser ™ manufactured by IRIS Technology Solutions S.L.

The adapter module with sapphire window allows easy integration of the Visum NIR In-Line™ analyser via a tri clamp connection. There are different sizes of the adapter module depending on the blending machine’s own configurations.

Unlike other analysers on the market, the Visum NIR In-Line™ is a self-contained analyser (embedded computer) and can communicate with multiple communication protocols. It also complies with the pharmaceutical regulation 21 CFR Part 11 (FDA), the requirements of the American (USP) and European (Ph. Eur.) Pharmacopoeia and the European Medicines Agency (EMA) Guidelines 2014 and 2023.

In its Blender version, the Visum NIR In-Line™ analyser is wireless, powered by rechargeable and replaceable batteries with a battery life of more than 3 hours and connected via Wi-Fi, as shown in the image below.

 

Image 2: Visum NIR In-Line™ analyser in a blending process monitoring cycle.

Control of the blending end point

Table 1: Visum NIR In-Line analyser ™ technical specifications

Conclusions

The IRIS Technology Solutions S.L. In-Line™ NIR analyser presents a more robust and realistic dynamic method for blending process monitoring than the Moving-block Standard Deviation (MBSD) algorithm  in that it is based on the quadratic mean of two successive spectra and not on the average of the standard deviation as a similarity index used by the MBSD approach.

As it has an embedded computer, it does not need to be connected to other electronic devices or external computers, making it an excellent stand-alone tool for working at the plant production level and in GMP environments.

In addition, it has a much larger illumination and spectrum acquisition area than other NIR analysers, especially those very small ones, with a resolution of 256 pixels, obtaining more chemical information and spectral quality for optimal monitoring of each blending cycle.

By IRIS Technology Solutions

You may also like

plastics

Challenge, Environment9 June 2020

Transforming the plastics sector into circular economy

Among the 60 million tonnes of plastic produced in Europe every year, only 30% of the total is recycled and the 79% of plastic waste has ended up in landfills or as litter in the natural environment. This is a fact that will produce an environmental disaster in a not too far future.

Challenge, Environment9 June 2020

Transforming the plastics sector into circular economy

plastics
expoquimia

Digitalization, Industry-4-01 June 2023

IRIS Technology presents its solutions at Expoquimia 2023

Digitalization, Industry-4-01 June 2023

IRIS Technology presents its solutions at Expoquimia 2023

expoquimia

Industry-4-0, Innovation25 January 2024

Plastic identification, verification and classification using Visum Palm™

Industry-4-0, Innovation25 January 2024

Plastic identification, verification and classification using Visum Palm™

Follow us

CONTACT INFO

Carretera d’Esplugues 39-41
08940 Cornellà de LLobregat
Barcelona, Spain
+34 935 54 25 00
info@iris-eng.com

Services

Process & Quality Control Systems
Digital Analytics Platforms
Research, Development & Innovation
Digital kit

Legal

Legal Advice
Privacy Policy
Cookies Policy
Quality & R&D+i Policy
Complaint Channel
European Regional Development Fund
A way to make Europe
IRIS Technology Solutions SL, within the framework of the ICEX Next Program, has been supported by ICEX and co-financed by the European ERDF fund. The purpose of this support is to contribute to the international development of the company and the opening of new export markets.

Project promoted with ACCIÓ’s eTrade Program

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Do you have any issue or complaint with IRIS? Report it through our platform.

  • ES
  • FR
  • DE
  • IT
  • PT
  • PL
  • TK

© 2021 IRIS Technology. All rights reserved.

Visum Palm

DOWNLOAD DATASHEET

If you opt in above you accepted the Privacy Policy.

We use cookies to make sure that our website works correctly and that you have the best experience possible.
MORE INFO
CONFIGUREACCEPT ALL
Manage consent

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
Necessary
Always Enabled
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Functional
Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features.
CookieDurationDescription
wpEmojiSettingsSupportssessionWordPress sets this cookie when a user interacts with emojis on a WordPress site. It helps determine if the user's browser can display emojis properly.
Analytics
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc.
CookieDurationDescription
_gcl_au3 monthsGoogle Tag Manager sets the cookie to experiment advertisement efficiency of websites using their services.
Advertisement
Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. These cookies track visitors across websites and collect information to provide customized ads.
CookieDurationDescription
pi1 year 1 month 4 daysThe pi cookie is used by Bombora for audience targeting and advertising.
Others
Other uncategorized cookies are those that are being analyzed and have not been classified into a category as yet.
CookieDurationDescription
_lfa_test_cookie_storedless than a minuteDescription is currently not available.
69e6fqmk5 daysDescription is currently not available.
p9ny4ztz5 daysDescription is currently not available.
pk1 year 1 month 4 daysNo description available.
sk1 hourNo description available.
spvc1 hourNo description available.
vk1 year 1 month 4 daysNo description available.
z6nhrp8b5 daysDescription is currently not available.
Save & Accept
Powered by WebToffee Logo